Domestic Nuclear Detection Office

Combating Nuclear Smuggling: Adequate Testing for Radiation

By Jim Kouri

Thursday, September 27, 2007

The Department of Homeland Security's Domestic Nuclear Detection Office (DNDO) is responsible for addressing the threat of nuclear smuggling. Radiation detection portal monitors are key elements in our national defenses against such threats.

DHS has sponsored testing to develop new monitors, known as advanced spectroscopic portal (ASP) monitors.

In June 2006, DNDO issued its analysis. In October 2006, the Government Accountability Office concluded that DNDO did not provide a sound analytical basis for its decision to purchase and deploy ASP technology and recommended further testing of ASPs.

DNDO conducted this ASP testing at the Nevada Test Site (NTS) between February and March 2007. GAO's statement addresses the test methods DNDO used to demonstrate the performance capabilities of the ASPs and whether the NTS test results should be relied upon to make a full-scale production decision.

Based on the US government's analysis of DNDO's test plan, the test results, and discussions with experts from four national laboratories, security analysts are concerned that DNDO's tests were not an objective and rigorous assessment of the ASPs' capabilities.

The GAO, for example, has concerns with the DNDO's test methods including the following: DNDO used biased test methods that enhanced the performance of the ASPs.

Specifically, DNDO conducted numerous preliminary runs of almost all of the materials, and combinations of materials, that were used in the formal tests and then allowed ASP contractors to collect test data and adjust their systems to identify these materials. It is highly unlikely that such favorable circumstances would present themselves under real world conditions.

DNDO's NTS tests were not designed to test the limitations of the ASPs' detection capabilities--a critical oversight in DNDO's original test plan. DNDO did not use a sufficient amount of the type of materials that would mask or hide dangerous sources and that ASPs would likely encounter at ports of entry. DOE and national laboratory officials raised these concerns to DNDO in November 2006.

However, DNDO officials rejected their suggestion of including additional and more challenging masking materials because, according to DNDO, there would not be sufficient time to obtain them based on the deadline imposed by obtaining Secretarial Certification by June 26. 2007.

By not collaborating with DOE until late in the test planning process, DNDO missed an important opportunity to procure a broader, more representative set of well-vetted and characterized masking materials.

DNDO did not objectively test the performance of handheld detectors because they did not use a critical CBP standard operating procedure that is fundamental to this equipment's performance in the field.

Because of concerns raised that DNDO did not sufficiently test the limitations of ASPs, DNDO is attempting to compensate for weaknesses in the original test plan by conducting additional studies--essentially computer simulations.

While DNDO, CBP, and DOE have now reached an agreement to wait and see whether the results of these studies will provide useful data regarding the ASPs' capabilities, in our view and those of other experts, computer simulations are not as good as actual testing with nuclear and masking materials.


Pursuant to Title 17 U.S.C. 107, other copyrighted work is provided for educational purposes, research, critical comment, or debate without profit or payment. If you wish to use copyrighted material from this site for your own purposes beyond the 'fair use' exception, you must obtain permission from the copyright owner. Views are those of authors and not necessarily those of Canada Free Press. Content is Copyright 1997-2024 the individual authors. Site Copyright 1997-2024 Canada Free Press.Com Privacy Statement